PENGARUH PERUBAHAN KECEPATAN TERHADAP KARAKTERISTIK POMPA SENTRIFUGAL
Sari
This research aim to to know influence of speed turn around to characteristic pump sentripugal. Approach taken by test 2 pump of sentripugal with speed turn around variedly equal to 50 Rpm ( giration of permenit) as follows: 3250 rpm, 3200 rpm, 3150 rpm, 3100 rpm, 3050 rpm, 3000 rpm, 2950 rpm, 2900 rpm, 2850 rpm, 2800 rpm, 2750 rpm, 2650 rpm, 2600 rpm, 2250 rpm, 2550 rpm which is the each tested with the same time. To know influence between speed turn around with characteristic pump hence used with regretion analysis.
This analysis is obtained that change of speed have an effect on proportional to yielded capacities, change of speed have an effect on rank two quadratic to high depress which yielded and change of speed have an effect on rank 3 to yielded axis energy. Whereas constant pump efficiency.
Teks Lengkap:
PDFReferensi
A.J. Stefanof, Centrifugal and axial flow Pump, Jhon Willey & Son Inc, New York, 1967.
Austin H. Chuch, Centrifugal Pump and Blower, Jhon Willey & Son Inc, New York, 1986.
B. Nekrasof, Ilydrlics For Aeronautical Enginerings, Publishing, Mascow.Biachi, Bustram P, Hendraji, Pompa, Pradnya Paramita, Jakarta, 1979.
Depdikbud, Pompa Jilid I & II, PT. Jaya Pirusa, Jakarta 1979.
Fritz Dietzel, Turbinen Pump and Verdichter, Vogel Verlog Werburg, 1980
Nouwen Ing, A, Pompa Jilid I & II, Brahtore, Karya Aksara, Jakarta, 1981.
Stephen La Zarkieviez, Adam T Trasko Lanski, Impeler Pump, First Edition, Wydawnectwa Novkowo Techniczne.
Sularso Horou Tahara, Pompa dan Kompresor, Pradnya Paramita, Jakarta, 1983.
Utomo, Alat Pengangkat dan Pompa, PT. Pradnya Paramita, Jakarta, 1991.
Refbacks